CAL-4330 Request for Availability

CAL-4330, 6.5 Digit, Calibration Fixture for Use With the PXIe-4330 and the PXIe-4331

Rated 4.7/5 | 11 ratings

Actual item may vary if no part number is provided on quote request.

National Instruments - Accessories - CAL-4330
National Instruments - Accessories - CAL-4330 - Wiring
CAL-4330 New
CAL-4330 Refurbished

2 Year Warranty Included

Free Ground Shipping

NIST Calibration Available

Request a Quote

Please fill out the form below to send in your quote request and a representative will contact you with a formal quote. View blog post on Model Name vs. Part Numbers

+Add more parts

Avg. Response Time: 15 min

Prefer to send a text message?

Text your name, e-mail, and parts to quote to:   1-919-809-5227

National Instruments CAL-4330 Calibration Fixture

The National Instruments CAL-4330 (Part Numbers: 786988-01, 787003-01) Calibration Fixture is a vital component for preserving the precision and dependability of PXIe-4330 and PXIe-4331 devices. This fixture offers a controlled environment for testing and modifying different parameters, ensuring accurate calibration.

For optimal outcomes, use a Fluke 5520A/5522A calibrator with the CAL-4330. An alternate calibrator with similar specifications can be used if these particular models are not available. The necessary parameters are automated lead wire compensation, 2-wire output compensation, resistance values between 120 Ω and 1 kΩ with 0.01 Ω resolution, and an accuracy of 90 ppm or greater.

CAL-4330 comes with the cables needed to make connections easier. Two of these cables are 160-Pin DIN to 160-Pin DIN, which connect PXIe-2737 switch modules to the fixture. The other cable is a shielded cable (SH96F-96M-CAL4330), which connects the Device Under Test (DUT) to the CAL-4330.

Two DMMs, either PXI-4071 or PXIe-4081 devices, are among the test apparatus needed for calibration. These DMMs ought to be multiranging, with a 6 1/2-digit capability and an accuracy of at least 40 ppm for DC voltage and 80 ppm for resistance when measuring 4-wire resistance. Four PXIe-2737 switch modules are furthermore required for relay operations.

The CAL-4330 is designed to provide accurate readings in particular testing scenarios. It is advised to utilize twisted-pair wire to reduce noise and thermal offsets, use shielded copper wire for cable connections, and keep connections short to reduce noise interference. Stable operation conditions are achieved by keeping the relative humidity below 80% and the ambient temperature at 23°C ±5°C. In addition, it is advised to give the measurement circuitry at least 15 minutes to stabilize before running any experiments.

Model Name   CAL-4330   
Part Number(s)   786988-01, 787003-01   
ManufacturerNational Instruments (NI)   
Compatible Devices   PXIe-4330, PXIe-4331   
Calibrator Compatibility   Fluke 5520A/5522A or equivalent   
Cable (DIN to DIN)   160-Pin, NI part number 782417-02 (x2)   
Shielded Cable (DUT to CAL)   SH96F-96M-CAL4330, NI part number 787003-01   
DMM CompatibilityPXI-4071 or PXIe-4081 or equivalent   
DMM Accuracy (DC Voltage)   40 ppm of reading +6 ppm of range   
DMM Accuracy (Resistance)80 ppm of reading +6 ppm of range   
Switch ModulesPXIe-2737, 4x64 2-wire relay modules (x2)   
Test ConditionsAmbient temperature: 23 °C ±5 °C, 
Relative humidity: <80%   

Associated part numbers for CAL-4330:

National Instruments CAL-4330 Frequently Asked Questions

Why does the CAL-4330 have two part numbers?

Part number 786988-01 is the actual module, while Part number 787003-01 is a shielded cable for connecting the PXIe-4330/4331 to the CAL-4330.

Is the CAL-4330 compatible with other NI devices?

No, the CAL-4330 is specifically designed for the PXIe-4330/4331 modules.

What other devices are required to calibrate with the CAL-4330?

For optimal outcomes, use a Fluke 5520A/5522A calibrator with the CAL-4330. Two DMMs, either PXI-4071 or PXIe-4081 devices, are among the test apparatus needed for calibration. For relay operations, Four PXIe-2737 switch modules are furthermore required .

Delivery:

UPS, FedEX and DHL – Free Ground on all orders

Overnight, Next Day Air or Expedited shipping options available

International delivery available

Same day shipping for in-stock on location

All of our products are covered by our Apex Waves Warranty.

3 Year Warranty - New Surplus Parts

2 Year Warranty - Refurb / Fully Tested Parts

No hassle return policy.

Dedicated customer service team.

Payment:

Authorize.net Visa Master Card American Express Truist icon logo Better Business Bureau Dun & Bradstreet

Receive Price & Availability Today!

Ask About Our Tiered Calibration Levels

Option & Modules:

Confirm Your Requirements or Versions

Cost & Lead Time Available Upon Request for Service

Repair Evaluation: $150

Share this page:

Common Typos:

DAL-4330, CWL-4330, CAL-T330, CAL-43W0, CAL-433P
Why Buy From Apex Waves:
Video thumbnail for Apex Waves Unboxing Experience Video