NI-9213 In Stock | Ships in 3-5 Days

NI-9213, 16 Analog Input Channels, Spring Terminal Connection, Thermocouple Input Module

Rated 4.6/5 | 7 ratings

Actual item may vary if no part number is provided on quote request.

NI-9213 National Instruments Thermocouple Input Module  | Apex Waves | Image
NI-9213 National Instruments Thermocouple Input Module  | Apex Waves | Image
NI-9213 New
NI-9213 Refurbished

2 Year Warranty Included

Free Ground Shipping

NIST Calibration Available

Request a Quote

Please fill out the form below to send in your quote request and a representative will contact you with a formal quote. View blog post on Model Name vs. Part Numbers

+Add more parts

Avg. Response Time: 15 min

Prefer to send a text message?

Text your name, e-mail, and parts to quote to:   1-919-809-5227

National Instruments NI-9213 Thermocouple Input Module

The NI-9213 (Part Numbers: 780493-01780493-02785185-01 and 785185-02) Thermocouple Input Module is created by National Instruments to be used in conjunction with the CompactDAQ and CompactRIO chassis. This module will meet the requirements for applications such as advanced data acquisition and control. The NI-9213 can be transported between platforms without alterations and is also hot-swappable. This Thermocouple Input Module has 16 channels, a sample rate of 75 S per second, an autozero function, 250 Vrms Ch-Earth isolation continuous, and a spring terminal connection. The device is fitted with filtering for 50 Hz and 60 Hz noise, and has a weight of 5.8 oz.

The autozero channel on the National Instruments NI-9213 can be deducted from every thermocouple reading to adjust for offset mistakes. The autozero channel does not have to be utilized, although the model’s specifications assume that autozero is used for each sample. The NI-9213 Module also has two timing modes: high-resolution and high-speed. The high-resolution timing mode enhances preciseness and noise, while declining power line frequencies. On the other hand, the high-speed timing mode enhances signal bandwidth and the sample rate.

The NI-9213 Thermocouple Input Module operates using the NI-DAQmx driver software which is compatible with numerous types of software packages such as the LabVIEW Professional Development System for Windows, the NI LabVIEW FPGA Module, and the NI LabVIEW Real-Time Module, LabWindows/CVI, Microsoft Visual C++, Microsoft Visual Basic, Borland C++, and Microsoft .NET. The device can be configured using the Measurement & Automation Explorer (MAX) tool. Additionally, the module has a recommended calibration interval of at least one year. For the input circuitry process, the channels on the National Instruments NI-9213 Module all pass through a differential filter. The next step consists of multiplexing the channel. Furthermore, the channel is sampled by a 24-bit Delta-Sigma analog-to-digital converter (ADC). The channels have the same ground, COM, which is secluded from additional modules in the system. The device has an operating temperature of -40 °C to 70 °C, with a warm-up time of 15 minutes. Also, it has a voltage measurement range of ±78.125 mV, with an input current of 50 nA.

ModelNI-9213
ManufacturerNational Instruments
Part Numbers780493-01, 780493-02, 785185-01, 785185-02
SeriesC Series
TypeTemperature Input Module
Analog Input Channels16 Differential
Sample Rate75 S/s Maximum
Maximum Accuracy (Degrees C)2.25
Front Connection TypesSpring Terminal
Enclosed?Yes
Supported Sensor TypeThermocouples (All Standard)
Measurement Accuracy Example0.77 °C
Operating Temp Range-40 °C to 70 °C
Storage Temp Range-40 °C to 85 °C
Weight5.8 oz.
WarrantyThree Year Warranty
NI-9213 ManualUser Manual and Maintenance Manual Available for Download
PriceRequest a Quote for Pricing

Associated part numbers for NI-9213:

National Instruments NI-9213 Frequently Asked Questions

 

Question: How do I connect thermocouples to the NI-9213?

Answer: Certain part number versions of the input module are especially equipped with thermocouple (TC) connectors.

 

Question: What is the difference between the part numbers for the NI-9213 module?

Answer: Part number 780493-01 has a TC connection. Part number 780493-02 also has a TC connection but is conformal coated. Part number 785185-01 has a spring terminal connection, while part number 785185-02 is conformal coated with spring terminal connections.

 

Question: What safety features does the NI 9213 have?

Answer: The Temperature Input Module has a channel-to-earth ground double isolation barrier for safety, as well as noise immunity.

 

Question: What is the noise rejection rate of the module?

Answer: The NI-9213 has a 50 Hz/60 Hz noise rejection rate.

 

Question: What is the maximum sample rate of the NI-9213?

Answer: The maximum sample rate of the input module is 75 S/s.

Delivery:

UPS, FedEX and DHL – Free Ground on all orders

Overnight, Next Day Air or Expedited shipping options available

International delivery available

Same day shipping for in-stock on location

All of our products are covered by our Apex Waves Warranty.

3 Year Warranty - New Surplus Parts

2 Year Warranty - Refurb / Fully Tested Parts

No hassle return policy.

Dedicated customer service team.

Payment:

Authorize.net Visa Master Card American Express Truist icon logo Better Business Bureau Dun & Bradstreet

Receive Price & Availability Today!

Ask About Our Tiered Calibration Levels

Option & Modules:

Confirm Your Requirements or Versions

Cost & Lead Time Available Upon Request for Service

Repair Evaluation: $150

Share this page:

Common Typos:

JI-9213, NJ-9213, NK-9213, NI-P213, NI-9Q13
Why Buy From Apex Waves:
Video thumbnail for Apex Waves Unboxing Experience Video