Anonymous Verified Buyer
" Very responsive and helpful, competitive pricing. Good source! "
July 2025
PXI-2515, 32-Channel, PXI Signal Insertion Switch Module
Rated 4.9/5 | 9 ratings
Actual item may vary if no part number is provided on quote request.
✔ 2 Year Warranty Included
✔ Free Ground Shipping
✔ NIST Calibration Available
National Instruments PXI-2515 PXI Multiplexer Switching Module
The National Instruments PXI-2515 is a PXI Multiplexer Switching Module that permits connectivity by routing rapid digital I/O (DIO) signals between a device under test (DUT) and a fast NI DIO gadget or a parametric estimation gadget. The user can utilize modules, such as PXI source measurement units (SMU) and digital multimeters (DMM) PXI with fast computerized gadgets. With the PXI-2515 (Part Number: 778572-15), the user can perform parametric tests on digital pins without an outer network or impedance lag.
Since high voltages and currents are frequently related to fault insertion, NI takes the most extreme care with its FIUs with regards to security. All NI FIUs are compliant with IEC 61010-1 worldwide models and have had their designs verified through third-party agencies as UL. In addition, reliability is a key concern for the integrity of long-term tests because they depend on FET relay technology.
Cabling and availability are significant worries for fault insertion applications because of the potentially huge number of high voltage and high current channels that are commonly included. The NI PXI-2515 module offers both cabled connector alternatives and uncovered wire link choices that are particularly intended to ensure safety, reliability, and shielding the way to the signal terminals, offering a full connectivity solution.
The user can easily control NI PXI-2515 Multiplexer Switch Module with NI VeriStand software, which implies the user can manage the same environment that they utilize to configure real-time I/O, stimulus profiles, data logging, and alarming.
Model | PXI-2515 (778572-15) |
---|---|
Manufacturer | National Instruments |
Type | Signal Insertion Switch Module |
Channels | 3 |
Switch Bandwidth | 50 MHz |
Minimum Pulse Width | 150 ns |
Dimensions | 8.5 x 0.8 x 5.1 in. |
Weight | 8.7 oz. |
Warranty | 2-3 Year Warranty |
PXI-2515 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for PXI-2515:
National Instruments PXI-2515 Frequently Asked Questions
Question: What type of relays does the PXI-2515 have?
Answer: The PXI-2515 has reed relays.
Question: What is the typical skew for the NI PXI-2515?
Answer: The typical skew for the NI PXI-2515 is <130 ps channel-to-channel across all data channels and <290 ps channel-to-control across all data and control channels.
Question: What is the maximum switching voltage for the PXI-2515?
Answer: The maximum switching voltage for the PXI-2515 is 30 V, CAT 1 channel-to-ground.
Question: What type of I/O connectors does the PXI-2515 have?
Answer: The PXI-2515 has 2 BNC female and 2 VHDCI female I/O connectors.
NI-PXI-PXIE-2515-SPECIFICATIONS.PDF
PXI-PXIE-2515-LETTER-OF-VOLATILITY.PDF
Delivery:
No hassle return policy.
Dedicated customer service team.
Receive Price & Availability Today!
Ask About Our Tiered Calibration Levels