Anonymous Verified Buyer
" Very responsive and helpful, competitive pricing. Good source! "
July 2025
PXIe-6556, 200 MHz, 24 Channels, Digital Waveform Generator/Analyzer
Rated 5/5 | 8 ratings
Actual item may vary if no part number is provided on quote request.
✔ 2 Year Warranty Included
✔ Free Ground Shipping
✔ NIST Calibration Available
National Instruments PXIe-6556 Digital Waveform Generator/Analyzer
The PXIe-6556 (Part Numbers: 781949-02 and 781949-01) Digital Waveform Generator/Analyzer has 24 channels that are per pin parametric unit (PPMU) enabled, a 200 MHz maximum clock rate, and voltage levels from -2 V to 7 V or -1 V to 7V. The PPMU feature acts similarly to a force and measure unit, which can drive and measure currents and voltages. PPMU settings can be programmed separately for every channel. The difference between the two part numbers is that part number 781949-02 has 64 MB of memory for each channel, and part number 781949-01 has 8 MB of memory for each channel. The device (both part numbers) has a maximum data transfer rate of 200Mbit per second. All other specifications are the same. This model is well-suited for validation and production test. The NI PXIe-6556 can create or obtain digital information, as well as complete DC parametric measurements with ease.
Other beneficial features of the PXIe-6556 Digital Waveform Generator/Analyzer include: real-time hardware compare, data delay, scripting, and an onboard high-resolution clock. There are also more advanced features available on the NI PXIe-6556, such as timing and synchronization capabilities and the capability to complete advanced linking, information streaming, and looping with the 64 Mbits (for each channel) and scripting feature. Additionally, the PXIe-6556 can be integrated with other devices, including: power supplies, digitizers, and switches for a versatile, high-performing mixed-signal test system. The device weighs 28 oz, and has dimensions of 21.6 x 2.0 x 13.0 cm. Also, the device has an input and output protection range of -3 V to 8.5 V.
The device supports a variety of I/O connector types-SMA Jack, Combicon, and the 68-pin VHDCI. Also, it supports multiple software depending on the specification (Driver software, Application software, Test panel). These software are the NI-HSDIO driver software (version 1.8 and above), National Instruments Measurement and Automation Explorer (MAX) tool which is used in configuring the software.
The accessories that NI suggests for use with the NI PXIe-6556 include a shielded single-ended 1 m SHC68-C68-D4 Cable and an unshielded single-ended CB-2162 Digital I/O Accessory. These accessories will work with both versions of the PXIe-6556.
The PXIe-6556 is no longer available from National Instruments (NI), but the Digital Waveform Generator/Analyzer will remain available in perpetuity with Apex Waves!
Model | PXIe-6556 |
---|---|
Part Numbers | 781949-02 and 781949-01 |
Manufacturer | National Instruments |
HTS Code | 8471804000 |
Channels | 24 |
Maximum Clock Rate | 200 MHz |
Memory | 8 MB/ch or 64 MB/ch |
Maximum Data Rate | 200 Mbit/s |
Dimensions | 21.6 x 2.0 x 13.0 cm. |
Weight | 28 oz. |
Warranty | 2-3 Year Warranty |
PXIe-6556 Manual | User Manual and Maintenance Manual Available for Download |
Price | Contact a sales representative for a quote. |
Associated part numbers for PXIe-6556:
National Instruments PXIe-6556 Frequently Asked Questions
Question: What are the programmable voltage levels for VOH, VOL, VTT, VIH, and VIL on the PXIe 6556?
Answer: The PXIe 6556 uses -2.0 to 7.0 V per pin programmable voltage levels.
Question: What advanced ATE capabilities are available on the NI PXIe-6556?
Answer: The NI PXIe-6556 advanced ATE capabilities include active load, tight CH-to-CH skew, and external SMU integration.
Question: Why am I getting an Error -1074118505 when performing the NI PXIe 6556 calibration procedure?
Answer: If you’re getting an error – 1074118505 when performing the NI PXIe 6556 calibration procedure, it usually means the DMM to AUX I/O connection is not properly connected or interchanged.
Question: Is external SMU integration available on the NI PXIe-6556?
Answer: Yes, the NI PXIe-6556 does have external SMU integration.
Accessory Type | Model Name | Part Number |
---|---|---|
Cable | SHC68-C68-D4 (Shielded Recommended) | 781013-01 (0.55 m) |
196275-01 (1 m) | ||
781293-01 (2 m) | ||
132625-03 (3 m) | ||
C68-C68-D4 Cable (Unshielded) | 195949-01 | |
SHC68-H1X38 (Shielded, Flying Lead) | 192681-1R5 | |
Cable Adapter | 653x Cable Adapter | 195846-01 |
Screw Terminal Block (Shielded) | SCB-68 HSDIO | 782914-01 |
SCB-68A | 782536-01 | |
Screw Terminal Block (Unshielded, DIN Rail Mount) | CB-2162 | 778592-01 |
CB-68LP | 777145-01 | |
CB-68LPR | 777145-02 | |
Screw Terminal Block (Unshielded) | TBX-68 | 777141-01 |
Breakout Box | SMB-2163 | 778747-01 |
- | - | - |
*The device is compatible with SCSI accessories when using the 653x Cable Adapter. Without this adapter, VHDCI accessories must be used.
*The SCB-68 / SCB-68A must use Direct Feedthrough Mode for configuration.
NI-6555-6556-GETTING-STARTED-GUIDE.PDF
NI-HIGH-SPEED-DIGITAL-WAVEFORM-GENERATOR-ANALYZER-GETTING-STARTED-GUIDE.PDF
NI-PXIE-6555-6556-CALIBRATION-PROCEDURE.PDF
NI-PXIE-6555-6556-SPECIFICATIONS.PDF
NI-PXIE-6556-SPECIFICATIONS.PDF
OS Compatibility: …
Delivery:
No hassle return policy.
Dedicated customer service team.
Receive Price & Availability Today!
Ask About Our Tiered Calibration Levels
Option & Modules:
Confirm Your Requirements or Versions
Cost & Lead Time Available Upon Request for Service
Repair Evaluation: $150
Common Typos: