Anonymous Verified Buyer
" Very responsive and helpful, competitive pricing. Good source! "
July 2025
RM-4302, 32 Analog Input Channels, 10 μV Max at 23°C ±5° Voltage, NI Terminal Block
Rated 4.6/5 | 11 ratings
Actual item may vary if no part number is provided on quote request.
✔ 2 Year Warranty Included
✔ Free Ground Shipping
✔ NIST Calibration Available
National Instruments RM-4302 Terminal Block
The National Instruments RM-4302 (Part Number: 783872-01) Terminal Block is a multipurpose, industrial-grade tool for streamlining analog input connections in automation systems. This terminal block, which has 32 analog input channels with AI± differential input, allows accurate data collecting across a broad temperature range of 0°C to 55°C. With an offset voltage of 10 μV max at 23°C ±5°C and 4 μV typ at the same temperature, it ensures accurate measurements even in challenging environments.
The offset voltage stability, which is 0.5 μV/°C max and 0.05 μV/°C, ensures reliable operation at different temperatures. The external power input range supported by the RM-4302 Terminal Block is 6 VDC to 28 VDC, with a maximum current rating of 3.2 A. It has Positive Temperature Coefficient (PTC) resistor short circuit protection, which guarantees operating safety. Mechanically, the device has an RJ50 receptacle that is built to last—it can withstand up to 500 insertions before breaking. With a mechanical switch life of 5 × 10^7 cycles and an electrical switch life of 2 × 10^5 cycles, channel configuration switches that use electromechanical relays offer dependable performance. Connectivity options allow for flexible integration into a variety of industrial configurations.
These alternatives include 32 RJ50 connectors, one BNC, one 96-pin DIN, two COMBICON 2-position, and one COMBICON 4-position connector. The RM-4302 Terminal Block was designed with the environment in mind, guaranteeing dependable performance under a variety of circumstances. It functions in the 0°C to 55°C ambient temperature range with 10% to 90% relative humidity (non-condensing). It may be stored in environments between -40°C and 71°C and between 5% and 95% relative humidity. Adhering to strict shock and vibration regulations, the gadget can resist operational shocks up to 30 g in peak force as well as random vibrations between 5 and 500 Hz. It minimizes interference in industrial situations and complies with regulatory criteria for electromagnetic compatibility (EMC).
Model Name | RM-4302 |
---|---|
Part Number(s) | 783872-01 |
Analog Input Channels | 32 |
Offset Voltage | 10 μV max @ 23 °C ±5 °C; 4 μV typ @ 23 °C ±5 °C |
Offset Voltage Stability | 0.5 μV/°C max; 0.05 μV/°C |
External Power Voltage Range | 6 VDC to 28 VDC |
External Power Current Rating | 3.2 A max;100 mA per EX+ |
Protection Type | Short Circuit Protected |
Mean Insertions Before Failure | 500 |
Switch Type | Electromechanical Relay, Latching |
Mechanical Switch Life | 5 × 107 cycles |
Electrical Switch Life | 2 × 105 cycles |
Environmental Operating Temp | 0 °C to 55 °C |
Relative Humidity | 10% to 90% (non-condensing) |
Associated part numbers for RM-4302:
National Instruments RM-4302 Frequently Asked Questions
How many channels does the RM-4302 have?
The RM-4302 has 32 analog input channels.
What connectors are available on the RM-4302?
The RM-4302 features 32 RJ50 connectors, one BNC, one 96-pin DIN, two COMBICON 2-position, and one COMBICON 4-position connector.
What module is the RM-4302 compatible with?
The RM-4302 terminal block is for use with the PXI-4302 module.